51 research outputs found

    Measuring measuring: Toward a theory of proficiency with the Constructing Measures framework

    Get PDF
    This paper is relevant to measurement educators who are interested in the variability of understanding and use of the four building blocks in the Constructing Measures framework (Wilson, 2005). It proposes a uni-dimensional structure for understanding Wilson’s framework, and explores the evidence for and against this conceptualization. Constructed and fixed choice response items are utilized to collect responses from 72 participants who range in experience and expertise with constructing measures. The data was scored by two raters and was analyzed with the Rasch partial credit model using ConQuest (1998). Guided by the 1999 Testing Standards, analyses of validity and reliability evidence provide support for the construct theory and limited uses of the instrument pending item design modifications

    Flowcell Systems for Single Molecule Detection

    Get PDF
    The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation without interference from unincorporated NPs and without illuminating the polymerase-DNA complex

    Flowcell Systems for Single Molecule Detection

    Get PDF
    The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation without interference from unincorporated NPs and without illuminating the polymerase-DNA complex

    Aortoiliac hemodynamic and morphologic adaptation to chronic spinal cord injury

    Get PDF
    BackgroundReduced lower limb blood flow and resistive hemodynamic conditions potentially promote aortic inflammation and aneurysmal degeneration. We used abdominal ultrasonography, magnetic resonance imaging, and computational flow modeling to determine the relationship between reduced infrarenal aortic blood flow in chronic spinal cord injury (SCI) subjects and risk for abdominal aortic aneurysm (AAA) disease.MethodsAortic diameter in consecutive SCI subjects (n = 123) was determined via transabdominal ultrasonography. Aortic anatomic and physiologic data were acquired via magnetic resonance angiography (MRA; n = 5) and cine phase-contrast magnetic resonance flow imaging (n = 4) from SCI subjects whose aortic diameter was less than 3.0 cm by ultrasonography. Computational flow models were constructed from magnetic resonance data sets. Results were compared with those obtained from ambulatory control subjects (ultrasonography, n = 129; MRA/phase-contrast magnetic resonance flow imaging, n = 6) who were recruited at random from a larger pool of risk factor–matched individuals without known AAA disease.ResultsAge, sex distribution, and smoking histories were comparable between the SCI and control groups. In the SCI group, time since injury averaged 26 ± 13 years (mean ± SD). Aortic diameter was larger (P < .01), and the prevalence of large (≥2.5 cm; P < .01) or aneurysmal (≥3.0 cm; P < .05) aortas was greater in SCI subjects. Paradoxically, common iliac artery diameters were reduced in SCI subjects (<1.0 cm; 48% SCI vs 26% control; P < .0001). Focal preaneurysmal enlargement was noted in four of five SCI subjects by MRA. Flow modeling revealed normal flow volume, biphasic and reduced oscillatory flow, slower pressure decay, and reduced wall shear stress in the SCI infrarenal aorta.ConclusionsCharacteristic aortoiliac hemodynamic and morphologic adaptations occur in response to chronic SCI. Slower aortic pressure decay and reduced wall shear stress after SCI may contribute to mural degeneration, enlargement, and an increased prevalence of AAA disease

    Charge-Switch Nucleotides

    Get PDF
    The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation Without interference from unincorporated NPs and Without illuminating the polymerase-DNA complex

    Charge Switch Nucleotides

    Get PDF
    The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation Without interference from unincorporated NPs and Without illuminating the polymerase-DNA complex
    • …
    corecore